- Microscope: FEI TITAN Krios - Acceleration voltage (kV): 300 - Pixel size (A/pixel): 0.83 - Spherical aberration (Cs) : 2.7 - Defocus (nm): -800 to -1600 - Magnification:105000 - Detector: Gatan K3 BIOQUANTUM - Average electron dose per image (e-/A2): 50 - Number of frames per image: 49 - Number of images: 4967 - Please use 'gain.mrc' as the gain reference with the flip along Y-axis for CryoSPARC (without flipping/rotation for RELION). - Please omit the first frame, as it contains noise caused by an Digital Micrograph bug.
Files:
Available download options:
Archives and downloads the selected files into an uncompressed zip file.
Depending on the number and size of files to be downloaded, this can take an enormous amount of time.
Also, this feature is unstable and may not work properly, and checksums of downloaded files are not verified.
We recommend using rsync, aspera, globus, etc.
Download a list of selected files.
It is possible to download files by specifying the file list with rsync command, etc.
- Microscope: FEI TITAN Krios - Acceleration voltage (kV): 300 - Pixel size (A/pixel): 0.83 - Spherical aberration (Cs) : 2.7 - Defocus (nm): -800 to -1600 - Magnification:105000 - Detector: Gatan K3 BIOQUANTUM - Average electron dose per image (e-/A2): 51 - Number of frames per image: 49 - Number of images: 10255 - Please use 'gain.tiff' as the gain reference without flipping/rotation. - Please omit the first frame, as it contains noise caused by an Digital Micrograph bug.
Files:
Available download options:
Archives and downloads the selected files into an uncompressed zip file.
Depending on the number and size of files to be downloaded, this can take an enormous amount of time.
Also, this feature is unstable and may not work properly, and checksums of downloaded files are not verified.
We recommend using rsync, aspera, globus, etc.
Download a list of selected files.
It is possible to download files by specifying the file list with rsync command, etc.
- Microscope: FEI TITAN Krios - Acceleration voltage (kV): 300 - Pixel size (A/pixel): 0.83 - Spherical aberration (Cs) : 2.7 - Defocus (nm): -800 to -1600 - Magnification:105000 - Detector: Gatan K3 BIOQUANTUM - Average electron dose per image (e-/A2): 51 - Number of frames per image: 48 - Number of images: 2687 - Please use 'gain.tiff' as the gain reference without flipping/rotation. - Please omit the first frame, as it contains noise caused by an Digital Micrograph bug.
Files:
Available download options:
Archives and downloads the selected files into an uncompressed zip file.
Depending on the number and size of files to be downloaded, this can take an enormous amount of time.
Also, this feature is unstable and may not work properly, and checksums of downloaded files are not verified.
We recommend using rsync, aspera, globus, etc.
Download a list of selected files.
It is possible to download files by specifying the file list with rsync command, etc.