The tilt series stacks of .mrc files were obtained after motion correction of 10 frames, collected using a dose-symmetric scheme starting from a -8 degree pre-tilt and covering a range from -62 to +46 degrees, with a tilt increment of 2 degrees. Each wedge includes 4 tilts.
The tilt series stacks of .mrc files were obtained after motion correction of 10 frames, collected using a dose-symmetric scheme starting from a -8 degree pre-tilt and covering a range from -62 to +46 degrees, with a tilt increment of 3 degrees. Each wedge includes 2 tilts.
The tilt series stacks of .mrc files were obtained after motion correction of 10 frames, collected using a dose-symmetric scheme starting from a -9 degree pre-tilt and covering a range from -63 to +45 degrees, with a tilt increment of 3 degrees. Each wedge includes 2 tilts.