EMPIAR-13721
Cryo-EM structure of the hTUT4_mini:Lin28A:pre-let-7g_UUU complex [multiple data sets in TIFF format]
Publication:

Mechanistic insights into Lin28-dependent oligo-uridylylation of pre-let-7 by TUT4

Han X, Yamashita S, Tomita K

Nucleic acids research 54 (2026)

PMID: 41521656

Related EMDB entry:
Deposited:
2025-10-17
Released:
2026-10-06
Last modified:
2026-10-06
Imageset size:
7.75 TB
Imageset DOI:
Experimental metadata:
Download xml json
Deposited via PDBj
Contains:
  • micrographs - multiframe
1. 20240719_Tomita_TUT4_3_data
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
4296
Image size:
(5760, 4092)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(None, None)
Details:
- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.
Files:
Loading...
2. 20240724_Tomita_TUT4_2_data
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
9977
Image size:
(5760, 4092)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(None, None)
Details:
- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.
Files:
Loading...
3. 20240808_Tomita_TUT4_1_data
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
9818
Image size:
(5760, 4092)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(None, None)
Details:
- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.
Files:
Loading...
4. 20241129_Tomita_TUT4_gUUU_Au_1_data
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
6382
Image size:
(5760, 4092)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(None, None)
Details:
- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.
Files:
Loading...
5. 20241129_Tomita_TUT4_gUUU_Au_2_data
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
7290
Image size:
(5760, 4092)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(None, None)
Details:
- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.
Files:
Loading...