EMPIAR-11791
Single-Particle Cryo-EM of AAV2 at Various Tilts [multiple data sets in MRCS and MRC formats]
Publication:

Overcoming resolution attenuation during tilted cryo-EM data collection

Aiyer S, Baldwin PR, Tan SM, Shan Z, Oh J, Mehrani A, Bowman ME, Louie G, Passos DO, Đorđević-Marquardt S, Mietzsch M, Hull JA, Hoshika S, Barad BA, Grotjahn DA, McKenna R, Agbandje-McKenna M, Benner SA, Noel JAP, Wang D, Tan YZ, Lyumkis D

Nature communications 15 (2024)

PMID: 38195598

Deposited:
2023-11-23
Released:
2024-02-13
Last modified:
2024-02-13
Imageset size:
730.42 GB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
  • micrographs - single frame
  • picked particles - multiframe - processed
1. Unaligned multiframe movies of AAV2 collected at various tilts
Category:
micrographs - multiframe
Image format:
MRCS
No. of images or tilt series:
1229
Image size:
(3710, 3838)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(1.026, 1.026)
Details:
Movies collected using Titan Krios and K2 summit. Tilt angles of 0, 10, 20, 30, 40, 50 and 60 degrees were collected put into their respective folders. 200 frames were used, pixel size is 1.026 Å/pixel, total dose of 78.0 e-/Å2. Compressed using pbzip2. Gain reference is 17jun01a_01155404_17_3838x3710_norm_0.mrc and needs to be flipped upside down to use.
Files:
Loading...
2. Aligned and dose-weighted micrographs of AAV2 collected at various tilts
Category:
micrographs - single frame
Image format:
MRC
No. of images or tilt series:
1229
Image size:
(3710, 3838)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(1.026, 1.026)
Details:
Aligned and dose weighted using UCSF MotionCor2. Tilt angles of 0, 10, 20, 30, 40, 50 and 60 degrees were collected put into their respective folders.
Files:
Loading...
3. Polished and equalized particles of AAV2 collected at various tilts
Category:
picked particles - multiframe - processed
Image format:
MRCS
No. of images or tilt series:
7
Image size:
(600, 600)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(1.026, 1.026)
Details:
Final particle stack after particle polishing using Relion. The particles are equalized so that there are same number of particles per tilt angle with similar defocus distribution.
Files:
Loading...
Abe KM, Li G, He Q, Grant T, Lim CJ. (2024)
Fenn KL, Horne JE, Crossley JA, Böhringer N, Horne RJ, Schäberle TF, Calabrese AN, Radford SE, Ranson NA. (2024)
Hicks CW, Rahman S, Gloor SL, Fields JK, Husby NL, Vaidya A, Maier KE, Morgan M, Keogh MC, Wolberger C. (2024)
Gusach A, Lee Y, Khoshgrudi AN, Mukhaleva E, Ma N, Koers EJ, Chen Q, Edwards PC, Huang F, Kim J, Mancia F, Veprintsev DB, Vaidehi N, Weyand SN, Tate CG. (2024)
Kofler L, Grundmann L, Gerhalter M, Prattes M, Merl-Pham J, Zisser G, Grishkovskaya I, Hodirnau VV, Vareka M, Breinbauer R, Hauck SM, Haselbach D, Bergler H. (2024)