α4β7 integrin in the apo state: 1363 unaligned uncorrected movies were recorded automatically using SerialEM on a K3 camera in super-resolution mode on a Glacios microscope operated at 200 kV (Cs=2.7). The movies contain 100 frames and the super resolution pixel size is 0.561 Å/px. The total dose per movie is ~50 e/Å^2. The gain reference is also included as a .dm4 file.
Files:
Available download options:
This entry cannot be downloaded from PDBj.
Archives and downloads the selected files into an uncompressed zip file.
Depending on the number and size of files to be downloaded, this can take an enormous amount of time.
Also, this feature is unstable and may not work properly, and checksums of downloaded files are not verified.
We recommend using rsync, aspera, globus, etc.
Download a list of selected files.
It is possible to download files by specifying the file list with rsync command, etc.
α4β7 integrin in the apo state: 1363 unaligned uncorrected movies were recorded automatically using SerialEM on a K3 camera in super-resolution mode on a Glacios microscope operated at 200 kV (Cs=2.7). The total dose per micrograph is ~50 e/Å^2. Images were dose-weighted and motion-corrected in MotionCor2 via the RELION GUI. Images were binned by 2 using Fourier cropping and the binned pixel size is 1.122.
Files:
Available download options:
This entry cannot be downloaded from PDBj.
Archives and downloads the selected files into an uncompressed zip file.
Depending on the number and size of files to be downloaded, this can take an enormous amount of time.
Also, this feature is unstable and may not work properly, and checksums of downloaded files are not verified.
We recommend using rsync, aspera, globus, etc.
Download a list of selected files.
It is possible to download files by specifying the file list with rsync command, etc.
Stacks of 239117 particles selected after sequential 2D and 3D classification contributing to final reconstruction of α4β7 integrin in the apo state. Unaligned uncorrected movies were recorded automatically using SerialEM on a K3 camera in super-resolution mode on a Glacios microscope operated at 200 kV (Cs=2.7). The total dose per micrograph is ~50 e/Å^2. Images were dose-weighted and motion-corrected in MotionCor2 via the RELION GUI. Images were binned by 2 using Fourier cropping and the binned pixel size is 1.122.
Files:
Available download options:
This entry cannot be downloaded from PDBj.
Archives and downloads the selected files into an uncompressed zip file.
Depending on the number and size of files to be downloaded, this can take an enormous amount of time.
Also, this feature is unstable and may not work properly, and checksums of downloaded files are not verified.
We recommend using rsync, aspera, globus, etc.
Download a list of selected files.
It is possible to download files by specifying the file list with rsync command, etc.