EMPIAR-11635
cAMP-bound SpSLC9C1 in lipid nanodiscs [multiple data sets in TIFF format]
Publication:

Structures of a sperm-specific solute carrier gated by voltage and cAMP

Kalienkova V, Peter MF, Rheinberger J, Paulino C

(---)

Related EMDB entry:
Deposited:
2023-07-27
Released:
2023-12-01
Last modified:
2023-12-01
Imageset size:
4.76 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 1
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1706
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 53.599 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
2. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 2
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
159
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 53.599 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
3. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 3
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
818
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 53.599 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
4. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 4
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
3742
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.95 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
5. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 5
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
2585
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.95 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
6. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 6
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1528
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.95 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
7. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 7
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1336
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 50.117 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
8. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 8
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
2789
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.32 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
9. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 9
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
2708
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.32 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
10. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 10
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1749
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.32 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
11. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 11
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
6242
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 49.32 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided.
Files:
Loading...
12. Unaligned movie frames of cAMP-bound SpSLC9C1 in nanodiscs, dataset 12
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
138
Image size:
(3838, 3710)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(1.022, 1.022)
Details:
Unaligned movie frames (60 frames per movie), collected at 200 kV in counting mode. Total electron dose is 53.599 electrons/Å^2. Data were recorded with SerialEM using 3 x 3 multi-shot pattern. Movies are not gain-corrected, gain reference is provided. This dataset was excluded from the original workflow.
Files:
Loading...
Files:
Loading...

Ito F, Alvarez-Cabrera AL, Liu S, Yang H, Shiriaeva A, Zhou ZH, Chen XS. (2023)
Rigden DJ, Fernández XM. (2023)
Iudin A, Korir PK, Somasundharam S, Weyand S, Cattavitello C, Fonseca N, Salih O, Kleywegt GJ, Patwardhan A. (2023)
Serra Lleti JM, Steyer AM, Schieber NL, Neumann B, Tischer C, Hilsenstein V, Holtstrom M, Unrau D, Kirmse R, Lucocq JM, Pepperkok R, Schwab Y. (2023)
Caldwell BJ, Norris AS, Karbowski CF, Wiegand AM, Wysocki VH, Bell CE. (2022)