EMPIAR-11070
Tilt series of SARS-CoV-2 virions, Wuhan/Alpha/Beta/Delta variants [multiple data sets in MRC format]
Publication:

Electron cryotomography of SARS-CoV-2 virions reveals cylinder-shaped particles with a double layer RNP assembly

Calder LJ, Calcraft T, Hussain S, Harvey R, Rosenthal PB

Communications Biology 5 (2022)

Related EMDB entry:
Deposited:
2022-06-15
Released:
2022-11-11
Last modified:
2022-11-11
Imageset size:
120.53 GB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
  • tilt series
1. Unaligned tilt movies of SARS-CoV-2 virions (Wuhan strain)
Category:
micrographs - multiframe
Image format:
MRC
No. of images or tilt series:
533
Image size:
(3838, 3710)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(2.22, 2.22)
Details:
Movies have 4 frames each, corresponding to 2.38e-/A^2 per tilt. Tilt series collected +/-60deg in dose symmetric sequence, grouping 2 (0,+3,-3,-6,+6,+9,etc...). Tilt axis rotation angle is 177deg.
Files:
Loading...
2. Tilt series of SARS-CoV-2 virions (Alpha variant B.1.1.7)
Category:
tilt series
Image format:
MRC
No. of images or tilt series:
2
Image size:
(4096, 4096)
Pixel type:
UNSIGNED 16 BIT INTEGER
Pixel spacing:
(2.58, 2.58)
Details:
2.5e-/A^2 dose per tilt. Tilt series collected +/-57deg in dose symmetric sequence, grouping 2 (0,+3,-3,-6,+6,+9,etc...). Tilt axis rotation angle is -2deg.
Files:
Loading...
3. Tilt series of SARS-CoV-2 virions (Beta variant B.1.351)
Category:
tilt series
Image format:
MRC
No. of images or tilt series:
2
Image size:
(4096, 4096)
Pixel type:
UNSIGNED 16 BIT INTEGER
Pixel spacing:
(2.58, 2.58)
Details:
2.5e-/A^2 dose per tilt. Tilt series collected +/-57deg in dose symmetric sequence, grouping 2 (0,+3,-3,-6,+6,+9,etc...). Tilt axis rotation angle is -2deg.
Files:
Loading...
4. Tilt series of SARS-CoV-2 virions (Delta variant B.1.617)
Category:
tilt series
Image format:
MRC
No. of images or tilt series:
2
Image size:
(4096, 4096)
Pixel type:
UNSIGNED 16 BIT INTEGER
Pixel spacing:
(2.58, 2.58)
Details:
2.0e-/A^2 dose per tilt. Tilt series collected +/-60deg in dose symmetric sequence, grouping 2 (0,+3,-3,-6,+6,+9,etc...). Tilt axis rotation angle is -2deg.
Files:
Loading...
Files:
Loading...

Ito F, Alvarez-Cabrera AL, Liu S, Yang H, Shiriaeva A, Zhou ZH, Chen XS. (2023)
Rigden DJ, Fernández XM. (2023)
Iudin A, Korir PK, Somasundharam S, Weyand S, Cattavitello C, Fonseca N, Salih O, Kleywegt GJ, Patwardhan A. (2023)
Serra Lleti JM, Steyer AM, Schieber NL, Neumann B, Tischer C, Hilsenstein V, Holtstrom M, Unrau D, Kirmse R, Lucocq JM, Pepperkok R, Schwab Y. (2023)
Caldwell BJ, Norris AS, Karbowski CF, Wiegand AM, Wysocki VH, Bell CE. (2022)