EMPIAR-10824
Cryo electron micrographs of Pol delta-DNA-PCNA giving rise to various PCNA tilt angles [multiple data sets in MRC format]
Publication:

Structure of the processive human Pol δ holoenzyme

Lancey C, Tehseen M, Raducanu VS, Rashid F, Merino N, Ragan TJ, Savva CG, Zaher MS, Shirbini A, Blanco FJ, Hamdan SM, De Biasio A

Nature communications 11 (2020)

PMID: 32111820

Related EMDB entry:
Deposited:
2021-09-15
Released:
2021-10-26
Last modified:
2021-10-26
Imageset size:
4.01 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Cryo-electron micrographs of Pol delta holoenzyme giving rise to different tilted conformers, collection 2
Category:
micrographs - multiframe
Image format:
MRC
No. of images or tilt series:
1406
Image size:
(4096, 4096)
Pixel type:
SIGNED 16 BIT INTEGER
Pixel spacing:
(1.081, 1.081)
Details:
Images taken on a FEI Titan Krios G3 at 300kV with a Falcon 3 detector. Defocus -0.6 micrometers. Volta phase plate was used. Total dose = 36 e-/Å^2. Dataset includes 3 corrupted files, as file names suggest - these became corrupted after the deposited EMDB maps were obtained.
Files:
Loading...
2. Cryo-electron micrographs of Pol delta holoenzyme giving rise to different tilted conformers, collection 1
Category:
micrographs - multiframe
Image format:
MRC
No. of images or tilt series:
452
Image size:
(4096, 4096)
Pixel type:
SIGNED 16 BIT INTEGER
Pixel spacing:
(1.081, 1.081)
Details:
Images taken on a FEI Titan Krios G3 at 300kV with a Falcon 3 detector. Defocus -0.4 micrometers. Volta phase plate was used. Total dose = 36 e-/Å^2. Dataset includes 2 corrupted files, as file names suggest - these became corrupted after the deposited EMDB maps were obtained.
Files:
Loading...
3. Cryo-electron micrographs of Pol delta holoenzyme giving rise to different tilted conformers, collection 3
Category:
micrographs - multiframe
Image format:
MRC
No. of images or tilt series:
1717
Image size:
(4096, 4096)
Pixel type:
SIGNED 16 BIT INTEGER
Pixel spacing:
(1.081, 1.081)
Details:
Images taken on a FEI Titan Krios G3 at 300kV with a Falcon 3 detector. Defocus -0.6 micrometers. Volta phase plate was used. Total dose = 36 e-/Å^2.
Files:
Loading...
Kim K, Li H, Clarke OB. (2025)
Krentzel D, Elphick M, Domart MC, Peddie CJ, Laine RF, Shand C, Henriques R, Collinson LM, Jones ML. (2025)
Arora S, Pan SH, Kumar S, Singh SK, Chauhan U, Alhalabi W, Arya V, Alsulami BS, Hsu CH, Chui KT, Gupta BB. (2025)
Costa-Gomes B, Greer J, Juraschko N, Parkhurst J, Mirecka J, Famili M, Rangel-Smith C, Strickson O, Lowe A, Basham M, Burnley T. (2025)
Zamanos A, Koromilas P, Bouritsas G, Kastritis PL, Panagakis Y. (2025)
Straub MS, Harder OF, Mowry NJ, Barrass SV, Hruby J, Drabbels M, Lorenz UJ. (2025)
Liu HF, Zhou Y, Huang Q, Martin J, Bartesaghi A. (2025)
Duraisamy AK, Fonseca N, Kleywegt GJ, Patwardhan A, Morris KL. (2025)
Lee CS, Grba DN, Wright JJ, Ivanov BS, Hirst J. (2025)
Williams HM, Curtis WA, Haubner M, Hruby J, Drabbels M, Lorenz UJ. (2025)