EMPIAR-10624
Cryo Soft X-ray data for tetraspeck correlation [multiple data sets in MRC format]
Publication:

Sample preparation strategies for efficient correlation of 3D SIM and soft X-ray tomography data at cryogenic temperatures

Okolo CA, Kounatidis I, Groen J, Nahas KL, Balint S, Fish TM, Koronfel MA, Cortajarena AL, Dobbie IM, Pereiro E, Harkiolaki M

Nature protocols 16 (2021) 2851-2885

PMID: 33990802

Related EMDB entry:
Deposited:
2021-01-15
Released:
2021-02-12
Last modified:
2022-02-25
Imageset size:
6.78 GB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • tilt series
1. Cryo soft X-ray tomography reconstruction of NIH-3T3 cells
Category:
tilt series
Image format:
MRC
No. of images or tilt series:
3
Image size:
(984, 974)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(100.0, 100.0)
Details:
Data name :20200311_tomo04_3DS30_man.mrc
Collection date: 11/03/2020
Location: Mistral Beamline, Alba Synchrotron (Spain)
Sample: NIH-3T3 (CRL-1658)
Fluorophore: Mitotracker Red (CMXRos) exogenous administration
Fiducials: 100 nm Au Fiducial (BBI Solutions)
Support: Quantifoil on Au Finder grid (3 mm F2/2)

520 eV; 25 nm Zoneplate; 984 * 974 Pixel; 10 * 10 * 10 nm Voxel size
-65 to 65 degree rotation with steps of 1 degree (131 images).

Data is already normalized and deconvolved using the standard Mistral prep-processing pipeline
Alignment of the Raw data done using IMOD, reconstruction done using tomo3D with 30 iterations of SIRT
Files:
Loading...
2. Cryo Soft X-ray tomography of NIH-3T3 cells with Tetraspeck as correlative fiducial markers
Category:
tilt series
Image format:
MRC
No. of images or tilt series:
1
Image size:
(984, 974)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(100.0, 100.0)
Details:
Data name :20200312_tomo23_3DS30_man.mrc
Collection date: 12/03/2020
Location: Mistral Beamline, Alba Synchrotron (Spain)
Sample: NIH-3T3 (CRL-1658)
Fluorophore: Mitotracker Red (CMXRos) exogenous administration
Fiducials: 100 nm Au Fiducial (BBI Solutions) and 200 nm Tetraspeck
Support: Quantifoil on Au Finder grid (3 mm F2/2)

520 eV; 25 nm Zoneplate; 984 * 974 Pixel; 10 * 10 * 10 nm Voxel size
-65 to 65 degree rotation with steps of 1 degree (131 images).

Data is already normalized and deconvolved using the standard Mistral prep-processing pipeline
Alignment of the Raw data done using IMOD, reconstruction done using tomo3D with 30 iterations of SIRT
Files:
Loading...
3. Cryo Soft X-ray tomography of Tetraspeck on Quantifoil
Category:
tilt series
Image format:
MRC
No. of images or tilt series:
1
Image size:
(984, 974)
Pixel type:
32 BIT FLOAT
Pixel spacing:
(100.0, 100.0)
Details:
Data name :20200311_tomo03_3DS30_man.mrc
Collection date: 11/03/2020
Location: Mistral Beamline, Alba Synchrotron (Spain)
Sample: Tetraspeck on quantifoil
Fiducials: 100 nm Au Fiducial (BBI Solutions)
Support: Quantifoil on Au Finder grid (3 mm F2/2)

520 eV; 25 nm Zoneplate; 984 * 974 Pixel; 10 * 10 * 10 nm Voxel size
-65 to 65 degree rotation with steps of 1 degree (131 images).

Data is already normalized and deconvolved using the standard Mistral prep-processing pipeline
Alignment of the Raw data done using IMOD, reconstruction done using tomo3D with 30 iterations of SIRT
Files:
Loading...
Files:
Loading...

Ito F, Alvarez-Cabrera AL, Liu S, Yang H, Shiriaeva A, Zhou ZH, Chen XS. (2023)
Rigden DJ, Fernández XM. (2023)
Iudin A, Korir PK, Somasundharam S, Weyand S, Cattavitello C, Fonseca N, Salih O, Kleywegt GJ, Patwardhan A. (2023)
Serra Lleti JM, Steyer AM, Schieber NL, Neumann B, Tischer C, Hilsenstein V, Holtstrom M, Unrau D, Kirmse R, Lucocq JM, Pepperkok R, Schwab Y. (2023)
Caldwell BJ, Norris AS, Karbowski CF, Wiegand AM, Wysocki VH, Bell CE. (2022)