EMPIAR-10518
Cryo-EM structure of immunodominant protein P1 from human pathogen Mycoplasma pneumoniae on graphene oxide grid [multiple data sets in TIFF format]
Publication:

Immunodominant proteins P1 and P40/P90 from human pathogen Mycoplasma pneumoniae

Vizarraga D, Kawamoto A, Matsumoto U, Illanes R, Pérez-Luque R, Martín J, Mazzolini R, Bierge P, Pich OQ, Espasa M, Sanfeliu I, Esperalba J, Fernández-Huerta M, Scheffer MP, Pinyol J, Frangakis AS, Lluch-Senar M, Mori S, Shibayama K, Kenri T, Kato T, Namba K, Fita I, Miyata M, Aparicio D

Nature communications 11 (2020)

PMID: 33057023

Related EMDB entry:
Deposited:
2020-09-01
Released:
2020-11-11
Last modified:
2020-11-11
Imageset size:
8.04 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Unaligned 136-frame movies of human pathogen Mycoplasma pneumoniae P1
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
512
Image size:
(4096, 4096)
Pixel type:
SIGNED 16 BIT INTEGER
Pixel spacing:
(0.88, 0.88)
Details:
human pathogen Mycoplasma pneumoniae P1(particles have preferred orientations). Cryo-EM imaging was obtained using a Titan Krios operating at 300 kV acceleration voltage and equipped with a Cs corrector and a Falcon III direct electron detector. A total of 512 movies were obtained in the electron counting mode with a physical pixel size of 0.88 Å/pixel and total dose of 60 e/Å2 with 63.2 s exposure time. The data were automatically collected using EPU software with a defocus range of -1.25 to -2.75 µm and were fractionated into 136 movie frames.
Files:
Loading...
2. Unaligned 78-frame movies of human pathogen Mycoplasma pneumoniae P1
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
5469
Image size:
(4096, 4096)
Pixel type:
SIGNED 16 BIT INTEGER
Pixel spacing:
(0.69, 0.69)
Details:
human pathogen Mycoplasma pneumoniae P1 on graphene oxide grid. Cryo-EM imaging was obtained using a Titan Krios operating at 300 kV acceleration voltage and equipped with a Cs corrector and a Falcon III direct electron detector. A total of 5469 movies were obtained in the electron counting mode with a physical pixel size of 0.69 Å/pixel and total dose of 60 e/Å2 with 36.33 s exposure time. The data were automatically collected using EPU software with a defocus range of -0.75 to -2.75 µm and were fractionated into 78 movie frames.
Files:
Loading...
Files:
Loading...

Ito F, Alvarez-Cabrera AL, Liu S, Yang H, Shiriaeva A, Zhou ZH, Chen XS. (2023)
Rigden DJ, Fernández XM. (2023)
Iudin A, Korir PK, Somasundharam S, Weyand S, Cattavitello C, Fonseca N, Salih O, Kleywegt GJ, Patwardhan A. (2023)
Serra Lleti JM, Steyer AM, Schieber NL, Neumann B, Tischer C, Hilsenstein V, Holtstrom M, Unrau D, Kirmse R, Lucocq JM, Pepperkok R, Schwab Y. (2023)
Caldwell BJ, Norris AS, Karbowski CF, Wiegand AM, Wysocki VH, Bell CE. (2022)