EMPIAR-10561
Cryo-EM structure of the human CDK-activating kinase bound to the clinical inhibitor ICEC0942 [multiple data sets in TIFF format]
Publication:

2.5 Å-resolution structure of human CDK-activating kinase bound to the clinical inhibitor ICEC0942

Greber BJ, Remis J, Ali S, Nogales E

Biophysical journal 120 (2021) 677-686

PMID: 33476598

Related EMDB entry:
Deposited:
2020-10-30
Released:
2021-01-29
Last modified:
2021-06-04
Imageset size:
3.80 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Unaligned movies of human CAK-ICEC0942, dataset 1
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
2466
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.343, 0.343)
Details:
Unaligned super-resolution electron micrograph movies. 70 frames per movie with an accumulated exposure of 69 electrons per Angstrom squared. Movies are not gain corrected (gain reference is provided). Movies with numbers below 279 and those with numbers above that should be treated as separate optics groups (in addition to the groups for acquisition spots 1-9).
Files:
Loading...
2. Unaligned movies of human CAK-ICEC0942, dataset 3
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1179
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.343, 0.343)
Details:
Unaligned super-resolution electron micrograph movies without gain correction (gain reference is provided). 70 frames per movie with an accumulated exposure of 69 electrons per Angstrom squared. Acquisition spots 1-9 should be treated as separate optics groups.
Files:
Loading...
3. Unaligned movies of human CAK-ICEC0942, dataset 2
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
3340
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.343, 0.343)
Details:
Unaligned super-resolution electron micrograph movies without gain correction (gain reference is provided). 69 frames per movie with an accumulated exposure of 69 electrons per Angstrom squared. Acquisition spots 1-9 should be treated as separate optics groups.
Files:
Loading...
Abe KM, Li G, He Q, Grant T, Lim CJ. (2024)
Fenn KL, Horne JE, Crossley JA, Böhringer N, Horne RJ, Schäberle TF, Calabrese AN, Radford SE, Ranson NA. (2024)
Hicks CW, Rahman S, Gloor SL, Fields JK, Husby NL, Vaidya A, Maier KE, Morgan M, Keogh MC, Wolberger C. (2024)
Gusach A, Lee Y, Khoshgrudi AN, Mukhaleva E, Ma N, Koers EJ, Chen Q, Edwards PC, Huang F, Kim J, Mancia F, Veprintsev DB, Vaidehi N, Weyand SN, Tate CG. (2024)
Kofler L, Grundmann L, Gerhalter M, Prattes M, Merl-Pham J, Zisser G, Grishkovskaya I, Hodirnau VV, Vareka M, Breinbauer R, Hauck SM, Haselbach D, Bergler H. (2024)