EMPIAR-10561
Cryo-EM structure of the human CDK-activating kinase bound to the clinical inhibitor ICEC0942 [multiple data sets in TIFF format]
Publication:

2.5 Å-resolution structure of human CDK-activating kinase bound to the clinical inhibitor ICEC0942

Greber BJ, Remis J, Ali S, Nogales E

Biophysical journal 120 (2021) 677-686

PMID: 33476598

Related EMDB entry:
Deposited:
2020-10-30
Released:
2021-01-29
Last modified:
2021-06-04
Imageset size:
4.18 TB
Imageset DOI:
Experimental metadata:
Download xml json
Contains:
  • micrographs - multiframe
1. Unaligned movies of human CAK-ICEC0942, dataset 1
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
2466
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.343, 0.343)
Details:
Unaligned super-resolution electron micrograph movies. 70 frames per movie with an accumulated exposure of 69 electrons per Angstrom squared. Movies are not gain corrected (gain reference is provided). Movies with numbers below 279 and those with numbers above that should be treated as separate optics groups (in addition to the groups for acquisition spots 1-9).
Files:
Loading...
2. Unaligned movies of human CAK-ICEC0942, dataset 3
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
1179
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.343, 0.343)
Details:
Unaligned super-resolution electron micrograph movies without gain correction (gain reference is provided). 70 frames per movie with an accumulated exposure of 69 electrons per Angstrom squared. Acquisition spots 1-9 should be treated as separate optics groups.
Files:
Loading...
3. Unaligned movies of human CAK-ICEC0942, dataset 2
Category:
micrographs - multiframe
Image format:
TIFF
No. of images or tilt series:
3340
Image size:
(11520, 8184)
Pixel type:
UNSIGNED BYTE
Pixel spacing:
(0.343, 0.343)
Details:
Unaligned super-resolution electron micrograph movies without gain correction (gain reference is provided). 69 frames per movie with an accumulated exposure of 69 electrons per Angstrom squared. Acquisition spots 1-9 should be treated as separate optics groups.
Files:
Loading...
Kim K, Li H, Clarke OB. (2025)
Krentzel D, Elphick M, Domart MC, Peddie CJ, Laine RF, Shand C, Henriques R, Collinson LM, Jones ML. (2025)
Arora S, Pan SH, Kumar S, Singh SK, Chauhan U, Alhalabi W, Arya V, Alsulami BS, Hsu CH, Chui KT, Gupta BB. (2025)
Costa-Gomes B, Greer J, Juraschko N, Parkhurst J, Mirecka J, Famili M, Rangel-Smith C, Strickson O, Lowe A, Basham M, Burnley T. (2025)
Zamanos A, Koromilas P, Bouritsas G, Kastritis PL, Panagakis Y. (2025)
Straub MS, Harder OF, Mowry NJ, Barrass SV, Hruby J, Drabbels M, Lorenz UJ. (2025)
Liu HF, Zhou Y, Huang Q, Martin J, Bartesaghi A. (2025)
Duraisamy AK, Fonseca N, Kleywegt GJ, Patwardhan A, Morris KL. (2025)
Lee CS, Grba DN, Wright JJ, Ivanov BS, Hirst J. (2025)
Williams HM, Curtis WA, Haubner M, Hruby J, Drabbels M, Lorenz UJ. (2025)